FX-3R Maintenance Guide
13-31
[Adjustment items after replacement]
When replacing the servo amplifier, it is necessary to set the axis selection with the rotary switch
(SW1) on the servo amplifier of each axis.
Open the front cover of the servo amplifier and turn the rotary switch (SW1) for the axis selection
so that the arrow mark indicates the following set value.
Make sure that the DIP switch (SW2) is OFF.
After the adjustment has been completed, turn ON the power to the main unit and turn it OFF.
After that, restart the operation.
Note. When the main unit is started up for the first time after the servo amplifier has been
replaced, do not perform the origin return.
Table 13-5-1-1 Rotary Switch Settings
Servo amplifier
Axis selection switch
set values
X (LF)
0
X (LR)
1
YL (LF)
0
YR (LF)
1
YL (LR)
2
YR (LR)
3
X (RF)
0
X (RR)
1
YL (RF)
0
YR (RF)
1
YL (RR)
2
YR (RR)
3
1
2
ON
SW1
SW2
13-5-2. Display Indication of XY Servo Amplifier
A 7-segment LED that indicates the status is mounted on the front of the XY servo amplifier.
Normally, this LED shows the status as described below.
Table 13-5-2-1 7-Segment LED Indication
Indication Ab
C#
d#
Contents
Initialization is in progress.
→
Servo OFF
→
Servo ON
∗
Axis No. is shown in the
“
#
”
portion. (See also the Table below.)
Table 13-5-2-2 7-Segment LED Indication
Axis Axis
No.
Axis Axis
No.
X (LF)-axes
01
X (RF)-axes
01
X (LR)-axes
02
X (RR)-axes
02
YL (LF)-axes
01
YL (RF)-axes
01
YR (LF)-axes
02
YR (RF)-axes
02
YL (LR)-axes
03
YL (RR)-axes
03
YR (LR)-axes
04
YR (RR)-axes
04
Rev. 1.00