FX-3R Maintenance Guide
3-8
3-3-6. Manual Setting Method for the F70R Fiber Sensor Amplifier
The amplifier setting method is different from the factory-set status. Set this amplifier manually.
- Setting the operation mode
Mode switch
d
Operation mode
c
Sensor function
- Selecting the sensor function (teaching mode setting method)
c
Switch the sensor mode switch from [RUN] to [SELECT]. [SELE] appears on the display.
d
Each time the button [1] (red) is pressed, the sensor function display changes sequentially in
the order of A, AV, T, TV, L, LV, S, H, and V. Select [T] and reset the mode switch to [RUN].
- Selecting the operation mode (light ON operation setting method)
c
Switch the sensor mode switch from [RUN] to [SELECT]. [SELE] appears on the display.
d
Each time the button [2] (black) is pressed, the operation mode display changes sequentially in
the order of L, LO, LF, LOF, D, DO, DF, and DOF. Select [L] and reset the mode switch to
[RUN].
- Selecting the electronic volume position
S = Manual setting of operation level
c
Switch the sensor mode switch from [RUN] to [SELECT]. [SELE] appears on the display.
d
Each time the button [1] (red) is pressed, the sensor function display changes sequentially in
the order of A, AV, T, TV, L, LV, S, H, and V. Select [S].
Blinking
Mode switch
e
Switch the sensor mode switch from [SELECT] to [MODE]. The numeric value of the electronic
volume blinks.
f
Reset the mode switch from [MODE] to [SELECT].
g
Each time the button [1] (red) is pressed, the sensor function display changes sequentially in
the order of A, AV, T, TV, L, LV, S, H, and V. Select [T] and reset the mode switch to [RUN].