FX-3R Maintenance Guide
1-2
Rev. 1.00
1-1-1. X-Axis
Magnescale Affixing Position
(1) Affix the magnescale while guiding it using the X_MSC install jig.
The affixing starting line for the LF/RF is indicated by the mark-off line on the left side when
viewed from the front and that for the LR/RR is indicated by the mark-off line on the left when
viewed from the rear.
Adjust the position of the Z-phase marking on the magnescale side to the mark-off line, and
then affix the magnescale.
Specification value: Magnescale affixing position (Displacement in the direction parallel with the
head movement)
±
0.1mm
Figure 1-1-1-1 Mounting Example of X_MSC Install Jig
40069368
X_MSC install jig
Magnescale