Installation and operating instructions: JUDO UNIDOS digital dosing pump systems JUD-KH 6-50 and 6-100 (cold water) / JUD-HH 6-50 and 6-100 (hot water)
All rights reserved.
JUDO Wasseraufbereitung GmbH
© JUDO Wasseraufbereitung GmbH
Postfach 380
D-71351 Winnenden
Translation into foreign languages and reproduction, even in excerpt form, is only permitted with special
approval.
Tel. +49 (0)7195-692-0
Fax +49 (0)7195-692-188
Revision level: 20.04.2017
E-Mail: [email protected]
Internet: www.judo.eu
14
Dosing quantity in contact operating mode via JUDO contact water meter
JUDO contact water meter
Q3
4
10
16
25
[m³/h]
Pulse sequence 2000 1000 500 333 [Pulse/m³]
Q1
0.03
0.07
0.1
0.1
[m³/h]
Q4
(short duration)
5
12
20
30
[m³/h]
Tab. 7: JUDO contact water meter
Q3 4
Q3 10
Q3 16
Q3 25
Dosing
Setting at system-induced back pressure
quantity
2
4
10
2
4
10
2
4
10
2
4
10
[bar]
10 ml/m³ 0.55 0.56 0.62 1.1 1.1 1.2 2.7 2.8 3.1 2.7 2.8 3.1 [%]
20 ml/m³ 1.1
1.1
1.2
2.2 2.3 2.5 5.5 5.7 6.2 5.5 5.7 6.2 [%]
30 ml/m³ 1.6
1.7
1.9
3.3 3.4 3.7 8.2 8.5 9.3 8.2 8.5 9.3 [%]
40 ml/m³ 2.2
2.3
2.5
4.4 4.5 5.0 11
11
12
11
11
12
[%]
50 ml/m³ 2.7
2.8
3.1
5.5 5.7 6.2 14
14
15
14
14
15
[%]
60 ml/m³ 3.3
3.4
3.7
6.6 6.8 7.4 16
17
19
16
17
19
[%]
70 ml/m³ 3.8
4.0
4.3
7.7 7.9 8.7 19
20
22
19
20
22
[%]
80 ml/m³ 4.4
4.5
4.9
8.8 9.0 9.9 22
23
25
22
23
25
[%]
90 ml/m³ 4.9
5.1
5.6
9.9 10
11
25
25
28
25
25
28
[%]
100 ml/m³ 5.5
5.7
6.2
11
11
12
27
28
31
27
28
31
[%]
120 ml/m³ 6.6
6.8
7.4
13
14
15
33
34
37
33
34
37
[%]
140 ml/m³ 7.7
7.9
8.7
15
16
17
38
40
43
38
40
43
[%]
160 ml/m³ 8.8
9.0
9.9
18
18
20
44
45
49
44
45
49
[%]
180 ml/m³ 9.9
10
11
20
20
22
49
51
56
49
51
56
[%]
200 ml/m³ 11
11
12
22
23
25
55
56
62
55
56
62
[%]
250 ml/m³ 14
14
15
27
28
31
69
71
77
69
71
77
[%]
300 ml/m³ 16
17
19
33
34
37
82
85
93
82
85
93
[%]
350 ml/m³ 19
20
22
38
40
43
96
99
96
99
[%]
400 ml/m³ 22
23
25
44
45
49
[%]
450 ml/m³ 25
25
28
49
51
56
[%]
500 ml/m³ 27
28
31
55
56
62
[%]
600 ml/m³ 33
34
37
66
68
74
[%]
700 ml/m³ 38
40
43
77
79
86
[%]
800 ml/m³ 44
45
49
88
90
99
[%]
900 ml/m³ 49
51
56
99
[%]
1000 ml/m³ 55
56
62
[%]
1100 ml/m³ 60
62
68
[%]
1200 ml/m³ 66
68
74
[%]
1300 ml/m³ 71
73
80
[%]
1400 ml/m³ 77
79
86
[%]
1500 ml/m³ 82
85
93
[%]
1600 ml/m³ 88
90
99
[%]
1700 ml/m³ 93
96
[%]
1800 ml/m³ 99
[%]
Tab. 8: Dosing quantity in contact operating mode via JUDO contact water meter