CONFIGURATION AND SPECIFICATIONS
1-19
1.3.2 Options
(1)
AC/DC Power supply unit (NBD-577C)
Source voltage
100/110/120/200/220/240VAC (typical)
90 - 121 / 180 - 242VAC (100V/220V manual switching)
50/60Hz (typical), 47.5 to 64Hz, Single phase
and 24VDC (21.6 - 31.2VDC)
Output voltage
AC operation: Typ. 24VDC, 19 - 35VDC
DC operation: DC input is relayed directly.
Operating temperature range
-15°C to +55°C
Storage temperature range
-25°C to +65°C
Humidity resistance
No abnormality after standing 4 hours in +40°C, 93% RH
Vibration resistance (3 axes)
2 Hz - 5 Hz to 13.2 Hz:
: Full amplitude ±1 mm±10%
13.2 Hz to 100 Hz:
: Maximum acceleration 7 m/s
2
fixed
No abnormality after testing resonance points or at 30 Hz for more
than 2 hours
(2)
Connection box (NQE-5183)
Operating temperature range
-15°C to +55°C
External interface
(1) Sensor input port: IEC61162-1/2
4ports
(2) Gyro data input port (NSK):
1port
(SENSOR3, multiple use)
(3) GNSS differential correction data input port: ITU-R M.823-2
1port
(SENSOR4, multiple use)
(4) AUX port: IEC61162-2
3ports
(5) Long-range communication port:
IEC61162-2
1port (AUX3, multiple use)
(6) Relay terminals
1port
Summary of Contents for JHS-183
Page 2: ... ...
Page 33: ...CONFIGURATION AND SPECIFICATIONS 1 21 1 4 2 Overall configuration ...
Page 58: ...INSTALLATIONS 3 8 3 Procedure 1 2 3 4 5 6 7 8 9 ...
Page 59: ...INSTALLATIONS 3 9 10 11 12 13 14 15 ...
Page 60: ...INSTALLATIONS 3 10 16 17 18 19 20 ...
Page 61: ...INSTALLATIONS 3 11 21 22 23 24 ...
Page 82: ...INSTALLATIONS 3 32 3 1 7 NQE 422A Junction box Unit mm Weight Approx 0 4kg Color 7 5BG 7 2 ...
Page 84: ...INSTALLATIONS 3 34 ...
Page 87: ...APPENDIX 4 3 4 1 2 NCM 983 AIS CONTROLLER 4 1 2 1 CHASSIS ...
Page 88: ...APPENDIX 4 4 4 1 2 2 BLOCK DIAGRAM FPC 26 A K ...
Page 101: ......