CONFIGURATION AND SPECIFICATIONS
1-22
Supplement for interconnection diagram
Supplement 1. ALR_OUT and ACK_IN connection
The ALR_OUT port is made up of relay contact.
If the system detects an error, The ALR_OUT relay works. The relay holds the operational state until the CLR key
of the AIS controller is pressed, a response command is received from AUX1 to AUX3 serial interfaces or the
active low signal is inputted from ACK_IN. The following table shows the relay functions.
If AIS is turned off, the condition is recognized as abnormal and ALR_OUT is activated.
AIS
NQE-5183 Connection Box
FUNCTION
ALR_OUT
NC Normally
Close
COM Common
NO Normally
Open
Specification of relay contact: 125VAC, 0.3A / 30VDC, 1A at resistance load
ACK_IN detects as signal input, when ACK_IN 0V.
Output voltage and maximum current; 5Vdc, 10mA
Supplement 2. Remote Maintenance System (RMS) connection
This equipment can connect to the one port of the follows for RMS (VDR).
- AUX3 port of Connection box (NQE-5183)
- NETWORK port (LAN) of AIS controller (NCM-983)
In case of using AUX3, AUX3 terminal is set for long-range function by initial setting, therefore it is necessary to
change the setting that PJRC sentence is valid. Refer to service manual “2.2.4.2 SENSOR SETTING” to see
detail.
Summary of Contents for JHS-183
Page 2: ... ...
Page 33: ...CONFIGURATION AND SPECIFICATIONS 1 21 1 4 2 Overall configuration ...
Page 58: ...INSTALLATIONS 3 8 3 Procedure 1 2 3 4 5 6 7 8 9 ...
Page 59: ...INSTALLATIONS 3 9 10 11 12 13 14 15 ...
Page 60: ...INSTALLATIONS 3 10 16 17 18 19 20 ...
Page 61: ...INSTALLATIONS 3 11 21 22 23 24 ...
Page 82: ...INSTALLATIONS 3 32 3 1 7 NQE 422A Junction box Unit mm Weight Approx 0 4kg Color 7 5BG 7 2 ...
Page 84: ...INSTALLATIONS 3 34 ...
Page 87: ...APPENDIX 4 3 4 1 2 NCM 983 AIS CONTROLLER 4 1 2 1 CHASSIS ...
Page 88: ...APPENDIX 4 4 4 1 2 2 BLOCK DIAGRAM FPC 26 A K ...
Page 101: ......