INSTALLATIONS
3-15
3.1.2.2
Back side of the controller and connectors
(1) GND
Connect the terminal to the Ship ground.
(2) TRANSPONDER
N-type connector which is connected to the AIS transponder
(3) 24VDC/DATA1
Connect the control cable (CFQ-9183A/D/F) for DC power source input and communication with
external units
No. Name
No. Name
1 24V+
8 SENSOR2;
GND-ISO
2 24V-
9 AUX1;
TX-A
3 SENSOR1;
RX-A 10
AUX1;
TX-B
4
SENSOR1; RX-B
11
AUX1; RX-A
5
SENSOR1; GND-ISO 12
AUX1; RX-B
6
SENSOR2; RX-A
13
AUX1; GND-ISO
7 SENSOR2;
RX-B 14
GND(SHEILD)
Connectors for option cable
(1)
(2)
(3)
A
B
C