INSTALLATIONS
3-26
3.1.3.3 Sub controller connection method
JHS-183 can connect to another AIS controller as the monitor controller.
The SUB controller (normal operation) is possible to operate normally except self diagnosis of the
transponder. At maintenance mode, some items are restricted.
Regarding the maintenance mode setting, refer to the service manual “2.2.4.2 Initial setting”.
(1) Connection
method
Control cable for the sub controller is connected to the AUX1 and the power source terminals.
Don't connect the sub controller to the transponder cable and each optional cable.
[Note]
- Connect the cable to the power source as shown above.
- The sub controller is not connected to each sensor port. Wrap the number 3 to 8 cables of
CFQ-9183 because of insulation protection.
- Make sure to connect the sub controller to AUX1 port. And wire Rx and Tx conversely.
- Objective Equipment: NCM-983 AIS CONTROLLER
Software version
: Ver.27 and later. (Disp and lan software.)
NQE-5183 CONNECTION BOX
Main Controller
SUB Controller
SUB
MAIN
Wire Rx and Tx conversely.
Summary of Contents for JHS-183
Page 2: ... ...
Page 33: ...CONFIGURATION AND SPECIFICATIONS 1 21 1 4 2 Overall configuration ...
Page 58: ...INSTALLATIONS 3 8 3 Procedure 1 2 3 4 5 6 7 8 9 ...
Page 59: ...INSTALLATIONS 3 9 10 11 12 13 14 15 ...
Page 60: ...INSTALLATIONS 3 10 16 17 18 19 20 ...
Page 61: ...INSTALLATIONS 3 11 21 22 23 24 ...
Page 82: ...INSTALLATIONS 3 32 3 1 7 NQE 422A Junction box Unit mm Weight Approx 0 4kg Color 7 5BG 7 2 ...
Page 84: ...INSTALLATIONS 3 34 ...
Page 87: ...APPENDIX 4 3 4 1 2 NCM 983 AIS CONTROLLER 4 1 2 1 CHASSIS ...
Page 88: ...APPENDIX 4 4 4 1 2 2 BLOCK DIAGRAM FPC 26 A K ...
Page 101: ......