Step #26 Aileron-to-Flap
Step #27 Aileron Differential
Step #28 Flap Rate, Camber Mix and Camber Adjust
S-58
S-59
This function gives added roll response by mixing
ailerons to flaps such that the entire trailing edge
functions as an aileron. In
FUNC.LIST
highlight
AIL
FLP M
. Press the
Selector
to access the Aileron-
to-flap mix. Highlight
CRU
then press the
Selector
selecting
Pos1
. This applies the same vales as selected
In
FUNC.LIST
highlight
DIFFEREN
. Press the
Selector
to access the Aileron differential menu. Highlight the
cruise aileron value then press the
Selector
to access
that value. With the flight mode switch in the middle
cruise mode, give a full right aileron command and rotate
previously in launch mode to cruise. If you choose a
different aileron-to-flap value, then select
Pos0
and adjust
the
Pos0
value to achieve the desired results. Press the
LIST
button to return to the Function Mode screen.
the
Selector
to achieve the desired aileron differential for
cruise. Press the
Selector
to
store the value. Now rotate
the
Selector
to highlight the cruise flap value and adjust
it to the desired position. Press the
LIST
button to return
to the Function Mode screen.
Most pilots prefer to have variable camber adjustment
during cruise. This enables fine adjustments in flight-
based conditions.
Important
: The flaperon and elevator values in the
camber mix menu are based on a percentage of the
programmed flap rate. The flap rates are defaulted
to 0% from the factory, so flaperon and elevator mix
values have no effect until the flap rate values are
set. Because of this, it’s mandatory to first adjust the
flap rates before adjusting the flaperon and elevator
camber mixes. Also remember that changing the flap
rate values affects the flaperon and elevator camber
mix.
Flap Rate
In
FUNC.LIST
highlight
Flaprn MX
. Press the
Selector
to access the Flap Rate menu. Highlight the cruise down
value then press the
Selector
to access this value. With
the flight mode switch in the middle cruise mode, move
the left side lever to the lowest position and adjust the
down value to the desired flap position. Now with the
flight mode switch in the middle cruise mode, move the
left side lever to the uppermost position and adjust the up
value to the desired flap position. Press the
LIST
button
to return to the Function Mode screen.
Flaperon Mix
Note
: You must set Flap rate before camber mix.
In
FUNC.LIST
highlight
Flaprn MX
. Press the
Selector
to access the Camber Mix menu. Highlight the cruise
FPRN
down value then press the
Selector
to access this
value. With the flight mode switch in the middle cruise
mode, move the left side lever to the lowest position and
adjust the down value to the desired flaperon position.
Press the
Selector
to store the value. Now with the flight
mode switch in the middle cruise mode, move the left side
lever to the uppermost position and adjust the up value
to the desired flaperon position and store by pressing
the
Selector
. Repeat the process for the up and down
elevator camber mix. Press the
LIST
button to return to
the Function Mode screen.
Summary of Contents for X9503 2.4
Page 43: ...A 56...
Page 103: ...S 68...