JS1 Jet Sustainer Flight Manual Supplement - Issue 1
Date of issue: 31.03.2016
Accepted section
Page 8–5
8.5. Configuration
The configuration menu consist of
Throttle configuration
Fuel configuration
Battery setup
8.5.1. Throttle configuration
The throttle configuration allows selection
of the throttle input between either,
controlled via the JDU Trust Dial (default)
or via an external analogue throttle. (The
second option is not available in JS
installations.)
In the “Throttle start RPM setting”, the power setting after start can
also be selected. The recommended setting is “IDLE”, as this setting
gives the pilot the opportunity to allow the temperatures to stabilize
before spooling up to higher power settings.
The system is designed to operate on 18
different power settings. These settings
are configurable on the ECU, using
Turbine Tool. To view the current settings,
select “Display thr. Out. Sett.”