JS1 Jet Sustainer Flight Manual Supplement - Issue 1
Date of issue: 31.03.2016
Accepted section
Page 5–33
5.2.1.2.
No idle speed
Error Description:
The RPM did not reach idle RPM after a pre-set time interval (factory
default is 30 seconds). As a result the start sequence was terminated.
Possible Causes:
Fuel valve not open
No fuel in fuel tanks
No fuel in start or main fuel lines – priming required
Pilot action required:
Check that fuel valve is in the Open position
Attempt to restart (if priming is required, up to 4 attempts are
normal)