Coffeemar
G-250
//
Coffee
MNP116M01GBV00
Date: 09/04/2013 Rev. 1
PAGE 78 OF 95
● Machine out of service
because waste bin is full.
● Machine out of service
because of moving arm
fault.
bottle and that the pump
works properly.
● Empty the waste bin. If it
is not full, check that the
floater is properly
positioned.
● Check the connections
between the bin filling micro
sensor and the control
card.
● Turn the machine off and
on to see whether the arm
goes through the complete
movement. If movement is
incorrect, check
connections with the control
card
● The product has not been
completely dispensed
● The pressure boiler is
not completely full.
● Possible volume counter
error
● Check whether, when the
machine is turned on, the
boiler is filled automatically.
● Carry out a volume
counter check
● Check the connection
between the volume
counter wire harness and
the control card. If
everything is OK, remove
the volume counter and its
water conduits and blow
towards the water outlet.
● Check that the volume
counter blade is not
blocked.
● Carry out a manual
washing cycle and check
that the machine gets rid of
water through the 2
solenoid valves.
● The machine displays
● Possible fault in coffee
● Turn the machine on and