SECTION 3 - CHASSIS & TURNTABLE
3-46
3121200
NOTE:
Series TG Torqlinks™ may have a rotor set with two stator
halves (8B) with a seal ring (4) between them and two sets
of seven vanes (8C). Discard seal ring only if stator halves
become disassembled during the service procedures.
NOTE:
A polished pattern on the wear plate from rotor rotation is
normal.
11.
Place rotor set (8) and wear plate (9) on a flat surface and
center rotor (8A) in stator (8B) such that two rotor lobes
(180 degrees apart) and a roller vane (8C) centerline are
on the same stator centerline. Check the rotor lobe to
roller vane clearance with a feeler gage at this common
centerline. If there is more than 0.005 inches (0.13 mm)
of clearance, replace rotor set
.
NOTE:
If rotor set (8) has two stator halves (8B & 8D) and two sets
of seven vanes (8C & 8E) as shown in the alternate con-
struction TG rotor set assembly view, check the rotor lobe
to roller vane clearance at both ends of rotor.
12.
Remove drive link (10) from coupling shaft (12) if it was
not removed with rotor set and wear plate. Inspect drive
link for cracks and worn or damaged splines. No percep-
tible lash (play) should be noted between mating spline
parts. Remove and discard seal ring (4) from housing
(18).
13.
Remove thrust bearing (11) from top of coupling shaft
(12). Inspect for wear, brinelling, corrosion and a full
complement of retained rollers.
14.
Check exposed portion of coupling shaft (12) to be sure
you have removed all signs of rust and corrosion which
might prevent its withdrawal through the seal and bear-
ing. Crocus cloth or fine emery paper may be used.
Summary of Contents for T500J
Page 1: ...Service and Maintenance Manual Model T500J PN 3121200 July 25 2018 Rev I AS NZS...
Page 2: ......
Page 16: ...xii 3121200 LIST OF TABLES TABLE NO TITLE PAGE NO This page left blank intentionally...
Page 36: ...SECTION 2 GENERAL 2 8 3121200 NOTES...
Page 143: ...SECTION 3 CHASSIS TURNTABLE 3121200 3 107 Figure 3 45 Battery Charger Schematic...
Page 234: ...SECTION 5 BASIC HYDRAULIC INFORMATION SCHEMATICS 5 60 3121200 NOTES...
Page 246: ...SECTION 6 JLG CONTROL SYSTEM 6 12 3121200 Figure 6 5 System Test Flow Chart Platform Tests...
Page 304: ...SECTION 7 BASIC ELECTRICAL INFORMATION SCHEMATICS 7 32 3121200 NOTES...
Page 305: ......