SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS
7-8
3121200
7.5
AMP CONNECTOR
Applying Silicone Dielectric Compound to AMP
Connectors
Silicone Dielectric Compound must be used on the AMP con-
nections for the following reasons:
• To prevent oxidation at the mechanical joint between male
and female pins.
• To prevent electrical malfunction caused by low level con-
ductivity between pins when wet.
Use the following procedure to apply Silicone Dielectric Com-
pound to the electrical connectors.
1.
To prevent oxidation and low level conductivity, silicone
dielectric grease must be packed completely around
male and female pins on the inside of the connector
after the mating of the housing to the header. This is
easily achieved by using a syringe to fill the header with
silicone dielectric compound, to a point just above the
top of the male pins inside the header. When assem-
bling the housing to the header, it is possible that the
housing will become air locked, thus preventing the
housing latch from engaging.
2.
Pierce one of the unused wire seals to allow the trapped
air inside the housing to escape.
3.
Install a hole plug into this and/or any unused wire seal
that has silicone dielectric compound escaping from it.
Assembly
Check to be sure the wedge lock is in the open, or as-shipped,
position (See Figure 7-11.). Proceed as follows:
1.
To insert a contact, push it straight into the appropriate
circuit cavity as far as it will go (See Figure 7-13.).
2.
Pull back on the contact wire with a force of 1 or 2 lbs. to
be sure the retention fingers are holding the contact
(See Figure 7-13.).
Figure 7-11. Connector Assembly Figure 1
Figure 7-12. AMP Connector
Summary of Contents for T500J
Page 1: ...Service and Maintenance Manual Model T500J PN 3121200 July 25 2018 Rev I AS NZS...
Page 2: ......
Page 16: ...xii 3121200 LIST OF TABLES TABLE NO TITLE PAGE NO This page left blank intentionally...
Page 36: ...SECTION 2 GENERAL 2 8 3121200 NOTES...
Page 143: ...SECTION 3 CHASSIS TURNTABLE 3121200 3 107 Figure 3 45 Battery Charger Schematic...
Page 234: ...SECTION 5 BASIC HYDRAULIC INFORMATION SCHEMATICS 5 60 3121200 NOTES...
Page 246: ...SECTION 6 JLG CONTROL SYSTEM 6 12 3121200 Figure 6 5 System Test Flow Chart Platform Tests...
Page 304: ...SECTION 7 BASIC ELECTRICAL INFORMATION SCHEMATICS 7 32 3121200 NOTES...
Page 305: ......