SECTION 6 - JLG CONTROL SYSTEM
3121200
6-25
Note 1: Personality settings can be adjusted anywhere within the adjustment range in order to achieve optimum machine performance.
Note 2: Stop watch should be start when function starts. The exception is the drive function.The machine should have a running start.Stop watch as you cross the start line.
The drive distance is 25 feet.
Note 3: Unless noted, function speeds should be measured from the platform with one operator.
Note 4: All test should be done with the oil temp above 65°F (15.5°C).
Note 5: Ranges shown in "( )" are exceptions for Gas-powered machines.
Note 3: With swing motor P/N 3160182 optimum performance is achieved with these settings:
SWING, MAX (RT OR LT): Electric = 18%, gas = 61%, time = 85-105 seconds
With swing motor P/N 3160331 optimum performance is achieved with these settings:
SWING, MAX (RT OR LT): Electric = 34%, time=75-95; gas = 60%, time = 65-85 seconds
4150561-H
Table 6-4. Machine Model Adjustments and Speeds - CE Only
FUNCTION
ADJUSTMENT
1,4
MODEL DEFAULTS
MODEL TIME RANGE (SECONDS)
2,3
RANGES
5
Electric
Gas
Electric
Gas
Summary of Contents for T500J
Page 1: ...Service and Maintenance Manual Model T500J PN 3121200 July 25 2018 Rev I AS NZS...
Page 2: ......
Page 16: ...xii 3121200 LIST OF TABLES TABLE NO TITLE PAGE NO This page left blank intentionally...
Page 36: ...SECTION 2 GENERAL 2 8 3121200 NOTES...
Page 143: ...SECTION 3 CHASSIS TURNTABLE 3121200 3 107 Figure 3 45 Battery Charger Schematic...
Page 234: ...SECTION 5 BASIC HYDRAULIC INFORMATION SCHEMATICS 5 60 3121200 NOTES...
Page 246: ...SECTION 6 JLG CONTROL SYSTEM 6 12 3121200 Figure 6 5 System Test Flow Chart Platform Tests...
Page 304: ...SECTION 7 BASIC ELECTRICAL INFORMATION SCHEMATICS 7 32 3121200 NOTES...
Page 305: ......