SECTION 4 - BOOM & PLATFORM
4-16
3121200
4.9
BOOM SENSORS
There are two mechanical sensors that are standard on the
machine which sense the boom state. One is located on the
side of the base boom and senses when the boom is fully tele-
scoped in. The other sensor, which is mounted to the side of
the upright, senses whether the main boom is elevated and is
activated by a cam on the lift cylinder bushing.
Boom Elevation Limit Switch
1.
Set the limit switch to trip at 3.8° above horizontal (Main
Boom Position).
2.
Set the switch to reset at 1° below horizontal (Main
Boom Position).
3.
Route harness through center of turntable and chassis
plug harness into connector labeled transport limit
switch provided with frame harness.
BOOM
ELEVATION
LIMIT
SWITCH