Cleaning and maintenance
11/2021
1027959-00A
Operating instructions – 55/70
5.8.1
Low pressure lamps
Replace faulty low-pressure lamps immediately.
Always replace the entire set of lamps after the specified operating time.
–
Turn 90° and carefully remove from the socket.
–
Low-pressure lamps possess a reflector which directs the light outwards.
The lamps must be mounted in such a way that the rear side of the re-
flector is located on the inside of the unit.
–
Push the pins vertically into the socket from above.
–
Turn the lamp 90°.
The lettering must be oriented towards the outside (i.e. towards the tan-
ning room or towards the user).