6
JH INDUSTIRES INC.
SAFETY PRACTICES,
CONTINUED
INSTALLATION, MAINTENANCE AND SERVICE
Place barricades on the dock floor around the dock
leveler final location and in the driveway in front of
the dockleveler final location while installing,
maintaining or repairing the dock leveler.
PUT THE MAINTENANCE STRUT IN PLACE
before doing any maintenance or repair under the
dock leveler.
(See Maintenance pages 23
-
27)
When working on any electrical units, after raising,
disconnect the power and properly tag or lock out
before doing any maintenance or repair under the
dock lever.
All electrical troubleshooting or repair must be done
by a qualified technician and must meet applicable
codes.
If it is necessary to make troubleshooting checks
inside the control box with the power on, USE
EXTREME CAUTION! Do not place fingers or
un
-
insulated tools inside the control box. Touching
wires or other parts inside the control box could
result in electrical shock, death or serious injury.
Truck Bed Position from
Dock (in.)
EOD Grade (%)
RAMP
LIP
ABOVE
DOCK
5.0
28.3
3.1
4.5
26.4
1.4
4.0
24.5
-
0.4
3.5
22.7
-
2.1
3.0
20.8
-
3.9
2.5
19.0
-
5.6
2.0
17.2
-
7.4
1.5
15.4
-
9.2
1.0
13.6
-
11.0
0.5
11.8
-
12.7
0.0
10.0
-
14.4
Truck Bed Position from
Dock (in.)
EOD Grade (%)
RAMP
LIP
BELOW
DOCK
0.0
10.0
-
14.4
0.5
8.3
-
16.3
1.0
6.5
-
18.1
1.5
4.8
-
19.9
2.0
3.0
-
21.8
2.5
1.2
-
23.6
3.0
-
0.5
-
25.5
3.5
-
2.3
-
27.4
4.0
-
4.0
-
29.3
4.5
-
5.8
-
31.2
5.0
-
7.5
-
33.1
EOD GRADE CHART
FIGURE 1
-
EOD Grade Chart
WARNING
!
Verify with the manufacturers of all equipment to
be used on your specific edge
-
of
-
dock leveler, to
ensure that operating equipment at all specified
grades are within safe operation. Do not operate
any equipment that will not safely operate at any
of the grades shown. Failure to do so could
result in death or serious injury.