34
JH INDUSTIRES INC.
SINGLE PHASE 120VAC ELECTRICAL SCHEMATIC
T4
T2
T3
T1
LINE
LOW VOLTAGE
MOTOR WIRING DIAGRAM
115V, SINGLE PHASE, 50/60 Hz
Before doing any electrical work, make certain that
all power sources are disconnected and properly
tagged or locked out per OSHA requirements. All
electrical work must be done by a qualified
technician and must meet all applicable codes.
Failure to do so could result in electrical shock,
serious injury or death.
WARNING
!
WIRE CONNECTIONS (IN FIELD):
20amp Disconnect to Terminal Block Connections
Disconnect Hot to A105 (Black 12ga.)
Disconnect Common to A103 (White 12ga.)
Disconnect Ground to A113 (Green 12ga.)
Terminal Block to Motor Box
A111 to T1 & T3 on Motor (Black 12ga.)
A112 to T2 & T4 on Motor (White 12ga.)
A114 to Ground on Motor (Green 12ga.)
A109 to Black Wire on Solenoid 1 (Black 18ga.)
A110 to Black Wire on Solenoid 2 (Black 18ga.)
A106 to White Wire on Solenoid 1 (White 18ga.)
A107 to White Wire on Solenoid 2 (White 18ga.)
(Both White Wires from solenoids can be tied together only
needing one connection to A106 or A107)
A101 to Green Wire on Solenoid 1 (Green 18ga.)
A102 to Green Wire on Solenoid 2 (Green 18ga.)
(Both Ground wires from solenoids can be tied together only
needing one connection to A101 or A102)