25
JH INDUSTIRES INC.
MAINTENANCE,
CONTINUED
8.
Every 6 months verify that this is the latest and
most up to date manual by visiting the
manufacturer’s website. (Download or order as
needed)
9.
Hydraulic units only. Seasonally change the
hydraulic fluid for ambient temperatures change
if appropriate or if there is any evidence of
accumulating condensation creating water
contamination.
Do not over
-
adjust the extension springs.
Over
-
adjusting extension springs may cause the
dockleveler to bounce or float during use. Use of
an over
-
adjusted dockleveler could result in
death or serious injury.
OIL RECOMMENDATIONS
Do not use brake fluid or any other fluids not
approved by the manufacturer. Use of fluids not
approved by the manufacturer may attack the
hydraulic systems seals and hoses.
FLUIDS
1.
The first choice for fluid is Citco AW
-
46(200)
hydraulic fluid. This is the fluid normally supplied
by the factory and is suitable for a ambient
temperature range of
–
10° to +100° Fahrenheit
(
-
23°C to +38°C).
2.
Following is a recommended list of oils with a
compatible ambient temperature range.
A. Amoco Oil Co.
Rycon Oil No. 32, 46
Amoco AW 32, 46
B. Cities Service Oil Co.
Citgo AW Hyd. Oil 32, 46
Citgo All Temp. Hyd. Oil
C. Chevron USA
Chevron EP Hyd. Oil 32, 46
D. Fina Oil Co.
Fina AW 32, 46
Fina Automatic Transmission Fluid
Dexron II
E. Gulf Oil Corporation
Gulf Harmony 32 AW, 46 AW
F. Mobil Oil Corporation
DTE 15, 24, 25
Mobil Fluid #300 Transmission Fluid
G. Sentinel Lubricants Corp.
Sentinel SH
-
10 Hydraulic Oil
H. Shell Oil Co.
Tellus Hyd. Oil 32, 46
Tellus “T” Hyd. Oil 32, 46
I. Texaco Inc.
Rando Oil Hd
-
32, 46
J. Union 76
Xcel AW 46 (200)
3. For grease fittings use extreme pressure (EP)
style grease
A. Mobilux EP2
B. Shell Gradus S2 V220
C. Shell Retinax Grease EP2
D. Valvoline Crimson EP grease
CAUTION
!