IOM J500.32
Jerguson
®
LumaStar
™
2021.05
20
16633 Fol
tz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828
www.clark-
reliance.com ● [email protected]
8.3 Reflex Gage Bracket
.
NOTE: installation onto a Reflex Gauge requires removal of nuts on the gauge. Do not install illuminator
with gauge in service.
1. Install the brackets onto the illuminator leaving the bracket thumb screws loose. The brackets should
move freely up and down in the illuminator channel.
2. Remove top and bottom nuts from the Reflex Gauge on the side of the gauge that the illuminator is to be
installed on.
3. Position brackets onto studs, reinstall gauge nuts and tighten to the torque specified for your gauge.
4. Position illuminator so it is centered on the Reflex Gauge and tighten the bracket thumb screws. The
illuminator should be mounted as shown in Figure 18.
Reflex Bracket Mounting
Figure 18