7.2 Components
There are 4 main components required for the LED illuminator system: the light bar, a 24VDC power supply,
zener diode barrier, and cord with optional field-wireable connector. The cord may have more than one piece
depending on the customer requirements. Questions regarding acceptable applications should be directed to The
Clark-Reliance Corporation.
7.3 Installation Wiring
CAUTION:
Review the ratings prior to installation and again prior to start-up, to ensure proper operation
in the installed environment. Should there be any doubt as to the applicability of a unit for the installed
environment, consult the factory before placing the unit into service.
All installation steps should be performed by a qualified technician and should be executed in accordance with all
applicable national and local codes.
The light and field-wireable connector / enclosure should be checked to ensure that they contain no foreign
matter, and that the end connections are clean and undamaged.
Step by step instructions:
See Drawing CI-26677 for safety information for hazardous locations.
CAUTION
:
Before wiring LED illuminator, verify that the power circuit is off. The power supply and zener
diode barrier should be located in a non-hazardous area. The power supplied to the LED illuminator is
intrinsically safe. See figure 2.
Figure 2