IOM J500.32
Jerguson
®
LumaStar
™
2021.05
12
16633 Fol
tz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828
www.clark-
reliance.com ● [email protected]
Enclosure Option
1.
Open the cover of the connection enclosure. Insert the DC Line wires into the housing and connect to the
terminal block noting the polarity of the wire. The terminal block has been labelled with V + and GND to
aid installation. The DC output is pre-wired to the light bar. If this connection is removed during
installation, reconnect the white wire to V+ and green wire to GND. Failure to do so could result in
permanent damage to the power supply. Terminal torque value 4.5 LBF-IN. Wire size of #12-20 awg input
and Maximum of wire size of #18 awg output. See figure 3.
2.
The cord length from the remote mount enclosure to the LED illuminator is 8 foot. Wire length from the
power supply and zener diode barrier to the remote mount enclosure is up to 1800 feet using 2 strand
#18 wire AWG. Longer distances available depending on wire choice. See specifications.
3. Replace the cover on the power supply housing.
4.
Switch “ON” the power supply making sure the Illuminator is functioning properly, with all LED’s
illuminated.
5. Refer to the troubleshooting section in this manual if a portion or all of the LEDs do not illuminate.
Figure 3