IOM J500.32
Jerguson
®
LumaStar
™
2021.05
13
16633 Fol
tz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828
www.clark-
reliance.com ● [email protected]
Field-Wireable Option
1. Disassemble the field-wireable connector. See figure 4.
2. Connect DC lines to the field-wireable connector, V+ to pin #2 and connect GND to pin #4. See figure 5.
3. Wire length from the power supply and zener diode barrier using 2 strand #18 wire AWG is up to 700 feet.
Longer distances available depending on wire choice. Maximum wire size of #18 AWG and cord size of 6-
8mm. See specifications.
4. Reassemble the connector and attached to led illuminator.
5.
Switch “ON” the power supply making sure the Illuminator is functioning properly, with all LED’s
illuminated.
6. Refer to the troubleshooting section in this manual if a portion or all of the LEDs do not illuminate.
Figure 4
Figure 5