98
95
License missing
License error, a programmed function could not be started while
the necessary license is missing.
96
Firmware Checksum Failure
Please try to reload the XENAX® firmware again. If the error
persists, please contact Jenny Science.
97
Interlaced warnings
A new warning occurred before the state which led to the previous
warning was cleared. Please make sure process is setup in a way
where warnings cannot interlace (e.g. drive in soft limit and then
drive in limit switch, before soft limit was left).
98
AD Interrupt Nesting
Fatal Error
–
Please restart the XENAX® servo controller.
99
Encoder cable unplugged/disconnected
Motor encoder cable was disconnected. Please connect encoder
cable again and restart XENAX®.
„L“
Level I
2
C Bus
The Level of the I
2
C bus is not ok. Bus is blocked. Rotary motor
connected to a XENAX® controller with linear axis setup (DIP
Switch)? Or servo controller encoder connector defect. Test
encoder: disconnect encoder; if XENAX® starts normally, connector
is defect. If still not working, please contact Jenny Science for
support.
„n“
Level I
2
C Bus
I
2
C bus response is „nak“ (not acknowledged)
No communication on I
2
C bus, XENAX® internal or
LINAX®/ELAX®/ROTAX®, temperature check is not possible.
¹) Internal hardware failure of the device, please
contact Jenny Science