Chapter 8
Copper Testing
Testing voice service and Caller ID
OneExpert DSL User’s Guide
68
22052280, Revision 001
April 2014
Testing voice service and Caller ID
The POTS dialer allows you to place and receive voice calls to verify that the service is working
properly. You can also use the dialer for the following tasks:
– to drop battery for opens testing
– to establish a quiet termination for balance and noise tests
– to determine if loss at 1004 Hz is acceptable
– to test incoming caller ID number and name
The following procedure describes how to test voice service and caller ID.
To test voice service and caller ID
1
Connect the Tip (A), Ring (B), and Ground (Earth) leads to the line under test.
2
From the Copper menu, touch
POTS
.
The POTS Dialer menu appears.
3
Place a call.
a
Dial the number using the speed-dial (
Speed
system key) or manually enter the phone
number using the keypad.
b
To use pulse dialing, press the
Actions
system key and then select
Pulse Dialing
.
c
Press the
OK
key to initiate the call.
d
Speak into the microphone located above the OK key.
e
Optional.
To mute the microphone, press the
Actions
system key, and then select
Mute
(or Un Mute)
Microphone
.
The mute feature is only available when off hook.
f
Press the
On Hook
system key to end the call.
4
Receive a call.
a
Request someone to call you.
b
When the OneExpert DSL indicates an incoming call, press the
Off Hook
system key.
c
For lines that have caller ID, the name and number information appears in the box.
d
Optional.
To mute the microphone, press the
Actions
system key, and then select
Mute
(or Un Mute)
Microphone
.
e
The mute feature is only available when off hook.
f
Press the
On Hook
system key to end the call.
Testing voice service and caller ID is complete.