Specifications
Vibration Data
179
179
9811/5700-7
All Models
Table 10. Whole-Body Vibration Emission Under Representative Operating Conditions (According to the Intended
Use)
Whole-body vibration emission determined in accordance
with ISO 2631-1:1997 for this machine type is 0.38 m/s
2
normalised to an 8-hour reference period [A(8)] and based
upon a test cycle "defined in SAE J1166".
Note:
If SRS (Smooth Ride System) is fitted, the whole
body vibration emission for
D3
Roading (rough terrain) is
0.59 m/s
2
Hand-arm vibration determined in accordance with
dynamic test conditions defined in ISO 5349-2: 2001 does
not exceed 2.5 m/s
2
.
Note:
Errors bars are due to variations in vibration
emissions due to measurement uncertainty (50% in
accordance with EN 12096:1997).
Machine Operating Duties
Dominant Axis (X, Y or Z)
Machine Operating Duties
D1
Low Idle
D2
Roading (tarmac)
D3
Roading (rough terrain)
D4
Lift cycles
D5
Pick and place cycles