4-67
4.15.5 Setting a serial port
This display unit is equipped with three serial ports to send and receive data with external units. Since
each port can be set for input or output, set according to the purpose. However, as input/output of data
IN/OUT1 and data IN/OUT2 are commonly set, they cannot be set individually.
For instance, if data IN/OUT2 is set for input, data IN/OUT1 is automatically set for input.
In this case also, the baud rate and the output sentence can be set individually.
Determine the input output ports using the following table as the guideline.
Required port setting
Port setting
Data IN/OUT1
Data IN/OUT2
Data IN/OUT3
3 ports for output
Output Output Output
3 ports for input
Input
Input
Input
2 ports for output
1 port for input
Output Output Input
1 port for output
2 ports for input
Input Input Output
Although an output sentence, a cycle, and a bit rate can be set for each port, some bit rates and the
number of sentences may not be set. In this case, select the minimum sentence.
The following serial data can be set.
1) NMEA: Data is output in NMEA format. Available options are Version 1.5, 2.1, 2.3, and 4.0.
2) IEC:
Data is output in IEC format.
3) JRC
:
Data is output in JRC format. The bit rate is fixed 1200bps.
4) ROUTE WPT
:
The destination, route, and track in a memory can be transmitted and received using
DATA IN/OUT2, 3. (Refer to 4.15.17 Outptting Waypoint, Route and Track" for
detail)
4.15.5.1 Setting
transmission
The procedure for setting a serial port for transmission is shown below.
Sentence list
Setting port
Select an output format
Select SEND
Select BIT RATE
Select VERSION
(NMEA only)
Select an output cycle
Select an output sentence
BIT RATE selection screen
Procedure
Summary of Contents for JLR-7600
Page 2: ......
Page 11: ...ix...
Page 16: ......
Page 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Page 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Page 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Page 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Page 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Page 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Page 38: ...2 4...
Page 42: ...3 4...
Page 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Page 158: ...6 30...
Page 160: ...7 2...
Page 162: ...8 2...
Page 181: ......
Page 182: ......
Page 183: ......