4-66
Select VERSION (NMEA)
Select a sentence (IEC)
Select BIT RATE
Select an output sentence
Select an output cycle
Sentence list
4.15.4.4 Sharing
data
Data can be shared among the display units that are connected through the RS-485 network.
Set the data to be transmitted. Although setting for reception is not necessary, the baud rate must be
standardized among the display units.
For the linkage, set RS-485ID by referencing "4.15.4.1 Setting RS-485ID”.
Setting transmission
1. Refer to "4.15.1 Change to a maintenance mode" and display a maintenance menu.
2. Select “INTERFACE”, “DATA I/O”, and “RS-485” in this order by using
.
3. Select the output format to be set by using
.
1) Selecting
NMEA
4. When an output version is selected by using
, a sentence list is displayed.
Available versions are “1.5”, “2.1”, “2.3”, and “4.0”.
5. Select an output sentence by using
and set an output cycle.
A cycle can be selected within the range from 1 second to 9 seconds and if OFF is selected, the
sentence is not output.
6. Return control to the BIT RATE selection screen and select BIT RATE by using
.
Available bit rates are “38400”, “57600”, “76800”, and “115200”. Normally, “115200” is
recommended.
2) Selecting
IEC
In IEC, VERSION is not selected.
4. When “SENTENCE” is selected by using
, a sentence list is displayed.
5. Select an output sentence by using
and set an output cycle.
A cycle can be selected within the range from 1 second to 9 seconds and when OFF is selected,
the sentence is not output.
6. Return control to the BIT RATE selection screen and select BIT RATE by using
.
Available bit rates are “38400”, “57600”, “76800”, and “115200”. Normally, “115200” is
recommended.
Since data is transmitted between display units, some time lag occurs at the switching of
display.
When the bit rate is set to 115,200bps (Max speed), up to 4 sentences can be output.
Supplement
Select an output format
Procedure
Summary of Contents for JLR-7600
Page 2: ......
Page 11: ...ix...
Page 16: ......
Page 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Page 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Page 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Page 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Page 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Page 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Page 38: ...2 4...
Page 42: ...3 4...
Page 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Page 158: ...6 30...
Page 160: ...7 2...
Page 162: ...8 2...
Page 181: ......
Page 182: ......
Page 183: ......