4-32
4.6 Performing
Navigation
Registered and temporary routes can be started.
Routes can be selected by the following methods.
(1) Selecting a route from the route list
(2) Selecting a waypoint with the GOTO key
(3) Selecting a route with the GOTO key
(4) Creating a temporary route with the GOTO key
The waypoint is updated when own ship arrives the waypoint arrival circle.
4.6.1 Selecting a Route from the Route List
Routes can be selected from the route list and started.
1. Press
the
key to display the main menu.
2. Press
the
key to select "WPT/ROUTE" and "ROUTE START/END," and press the
key.
3. The route list will be displayed. Move the cursor to the route number you wish to start, and press
the
key.
An overview of each submenu is as follows.
(1) LEG CHANGE
You can set whether a waypoint is updated automatically or manually when own ship arrives
the waypoint arrival circle.
AUTO:
The waypoint is automatically updated to the next waypoint.
MANUAL: The waypoint is updated manually to the next waypoint.
When the arrival circle is reached, the following message will display. Press the
key to
update the waypoint.
(2) DIRECTION
You can set whether to perform navigation in the order of waypoints or starting from the final
waypoint.
ORDER: Navigation is performed in order the order of waypoints.
REVERSE: Navigation is performed starting from the final waypoint.
(3) SPEED SMOOTHING
When waypoint arrival time is calculated, ship speed is smoothed.
If the smoothing value is greater, the calculation result is stable but the difference becomes
larger.
In the sensor that calculates the ship speed, the ship speed may have already been
Procedure
UPDATE WPT
PLEASE PUSH ENT
Summary of Contents for JLR-7600
Page 2: ......
Page 11: ...ix...
Page 16: ......
Page 23: ...1 7 NBD 577C Power Supply Outline Drawing Unit mm Mass Approximately 5 4 kg...
Page 27: ...1 11 NQA 4351 Output Buffer Outline Drawing Unit mm Mass Approximately 0 8 kg...
Page 29: ...1 13 NCZ 1663 Select Switch Unit mm Mass Approximately 0 2 kg...
Page 30: ...1 14 NCZ 1663 Select Switch Flush Mounting Unit mm Mass Approximately 0 2 kg...
Page 31: ...1 15 NCZ 1537B Select Switch Flush Mounting Unit mm Mass Approximately 0 55 kg...
Page 33: ...1 17 NKG 94 Printer Outline Drawing Unit mm Mass 2 2 kg or less Printer Rack...
Page 38: ...2 4...
Page 42: ...3 4...
Page 138: ...6 10 Required installation space Unit mm Mount bottom 285 or more 190 or more 190 or more...
Page 158: ...6 30...
Page 160: ...7 2...
Page 162: ...8 2...
Page 181: ......
Page 182: ......
Page 183: ......