UV Medium Pressure | Installation & Operation Manual
IMPORTANT
We strongly recommend to interlock the UV system with the
recirculation pump contactor through one of its NO auxiliary contacts.
Recirculation Pump Contactor
19
20
-KAx
Figure 3. Wiring
21
22
21
22
ON
OFF
UV System
External Stop Control
Figure 4. Input Wiring
Model
240 V / 1-phase
JUV-MP 120
3 x AWG 16 (3 x 1.50 mm
2
)
JUV-MP 200
3 x AWG 16 (3 x 1.50 mm
2
)
JUV-MP 320
3 x AWG 12 (3 x 4 mm
2
)
JUV-MP 700
3 x AWG 12 (3 x 4 mm
2
)
3.6 UV Lamp Connection
Connect the UV lamp(s) installed within the UV
reactor to the corresponding terminals on the
control panel using the cables supplied with the
unit (LP-035) (see
Product Contents
section).
To do this, open the connection boxes on both
sides of the UV reactor, and connect the wires to
the corresponding terminals:
1. Lamp power (red)
2. Microswitch (black wires, labeled “1” and “2”)
WARNING
Unit is equipped with an automatic mechanism for shutting off the
power of the UV lamp whenever the cover is removed.
Once the connection is made, close the connection
boxes, making sure the seal is properly seated.
Figure 5. Wiring the UV Lamp