3. If it appears that the sensor quartz window is
fully transparent, place it again in its housing
as described below. If it is necessary to clean
the quartz window always do it with a soft cloth
soaked with alcohol.
4. Place and screw the UVX-SE sensor on its
housing in the body of the UV reactor.
5. Reconnect the sensor cable.
5.6 Verification of the Control Panel Fan
Frequency:
• You should check the fan of the control panel,
and clean up the grids and filters at least ONCE A
YEAR or if there is a noticeable stain.
Procedure:
1. Remove the protection grids using a suitable
screwdriver, as shown in the figure below.
Figure 16. Remove Fan Filter Grid
2. Clean and replace if necessary, the fiber filters
inside.
3. Mount again the grid in its position.
5.7 Wiper Driver (JUVMPAUTO Module)
Installation
During the installation of the wiper driver must
always be ensured that all elements of shaft are
correctly aligned with the existing mark [1] in the UV
reactor body, as shown in the figure.
5.8 System Isolation and Connections
Control
Frequency:
• You need to check the circuit breaker located
inside the control panel at least EACH TIME YOU
REPLACE THE UV LAMP, by pressing the TEST
button located on its front.
• You need to check the status of all connections,
especially the lamp power and the grounding of
both the control panel and the UV reactor, EACH
TIME YOU REPLACE THE LAMP.
Figure 17. Align Wiper Driver Shafts