Page 7
Jandy
®
UV Medium Pressure | Installation & Operation Manual
ENGLISH
2.3 Product Contents
The packaging should contain the following items:
• UV reactor
• Flow sensor:
EVC005 cable (5 m /16.4 ft)
1
• Temperature sensor:
TM 4411+ EVC005 cable (5 m /16.4 ft)
1
• Radiation sensor:
UVX-SE + EVC059 cable (5 m /16.4 ft)
1
• Automatic wiper WPA-05 cable
(5 m /16.4 ft)
1
• Control panel
• Lamp power cables LP-035 x2 (5 m /16.4 ft)
1
• Operation manual
1
Custom cable lengths may be supplied on demand.
NOTE: Disposing Old Product
Please act according to local rules and do not dispose
old products with normal household waste. The correct
disposal of old product will help prevent potential
harmful effects against the environment and health.
Section 3. Installation
3.1 General Considerations
• In order to guarantee a good state of
conservation, the Jandy UV MP system must
be installed in a dry and well-ventilated place at
the technical room. The protection degree of the
system does not allow outdoor installation.
• The temperature at the installation area must be
within 32°F (0°C) and 86°F (30°C) and the relative
humidity must not exceed 80%.
• Install the unit as far away as possible from any
storage of chemical products and sources of
moisture.
WARNING
Beware of corrosive atmosphere formation due to pH decreasing
solutions (specially, those ones based on hydrochloric acid “HCl”).
Do not install the system near to any stores of these chemicals. We
strongly recommend the use of chemicals based on sodium bisulphate
or diluted sulphuric acid.
3.2 UV Reactor Installation
The reactor of HELIOX UV MP systems can be
installed both horizontally and vertically, as shown in
the recommended installation diagrams (see
Figures
1 & 2
).
WARNING
Lamp must always remain horizontal to the ground, as if it is installed
so that the lamp is vertical, in the case of low flow, an air chamber may
be formed on its top, thus becoming part of the bulb exposed. Given
the high working temperature of medium pressure lamps, it is easily
understandable that this situation should always be avoided.
If the UV reactor is installed horizontally, sensors and wiper driver must
remain in the upper part.
Observe flow direction indications located on the UV chamber.
The reactor of the Jandy UV MP systems is made of
AISI 316 L stainless steel within which the UV lamp is
housed. The system should always be installed after
the filtration system, and before any other device in
the installation such as heat pumps, control systems,
dosage systems, salt electrolysis systems, etc.
The installation of the UV system should allow easy
access to the UV lamp by the user. The location of
the system must have an effective dimension that