Page 8
ENGLISH
Jandy
®
UV Medium Pressure | Installation & Operation Manual
allow the complete removal of the UV lamp from the
sleeve (approximately one meter on each side of the
connection boxes of the UV lamp).
It is highly recommended to install the Jandy UV MP
system in a place of the pipe that can be easily
isolated from the rest of the installation by two
valves, so that the tasks of maintenance can be
carried out with no need of partial or total draining of
the swimming pool. Where the system is installed on
a by-pass (recommended option), a valve to regulate
the flow must be introduced.
WARNING
Prior to the installation or replacement of any system component make
sure it has been previously disconnected from the mains, and there is
no water flow through it. Use only spare parts supplied by Jandy.
UV chamber grounding must be made in the two bonding lugs marked
*
on the end flanges using No. 8 AWG (US) and No. 6 AWG (Canada)
solid copper conductor and secured to the chamber by paint breaking
washers and nuts.
* IEC 60417, symbol 5019
1. Filter
2. Pump
3. UV reactor
4. Other equipment (dosage pumps,
controllers, heat exchangers, etc.)
Lamp Vertical
Lamp Horizontal
Floor
Figure 1. Recommended Installation — Horizontal