Page 9
Jandy
®
UV Medium Pressure | Installation & Operation Manual
ENGLISH
5. Filter
6. Pump
7. UV reactor
8. Other equipment (dosage pumps,
controllers, heat exchangers, etc.)
Figure 2. Recommended Installation — Vertical
3.3 Control Panel Installation
• Always install the control panel of the Jandy UV
MP system vertically and on a rigid surface (wall),
so that the touchscreen located on the front panel
is level with the eyes.
• Cooling fan and grids must not be blocked.
WARNING
The equipment should be assembled and handled by truly qualified
people.
Current electrical and accident prevention regulations should be
followed.
Do not attempt to alter the system to operate at a different voltage.
Both the power of the Jandy UV MP system control
panel and the interconnection of the UV lamp and the
sensors must be made at the terminal block at the
base inside the control panel. The control panel base
has a series of cable glands for the correct fixation of
the power cables and sensors. In any case the length
or section thereof should be amended, without first
consulting a Jandy authorized technician.
WARNING
Use copper conductors only.
Permanently connected.