8.3.71
MCP Mode
Function
Command String
Camera Response
Set MCP Mode
:MMD=[D]<cr> :o<cr>
Set the MCP exposure control mode. [D] is the mode
parameter.
0 = Manual.
1 = Auto.
Get MCP Mode
:MMD?<cr> :oMMD[D]<cr>
Enquire current MCP Mode. [D] is the current mode value.
0 = Manual.
1 = Auto.
8.3.72
MCP Minimum Gain
Function
Command String
Camera Response
Set MCP Min Gain
:MMG=[DDD]<cr> :o<cr>
Set the MCP minimum gain. [DDD] is the bias value code with a
range of 0-255. This is equivalent to a gain voltage of 2.5-5.0
volts.
Get MCP Min Gain
:MMG?<cr> :oMMG[DDD]<cr>
Enquire current MCP minimum gain. [DDD] is the current gain
code value with a range of 0-255. This is equivalent to a gain
voltage of 2.5-5.0 volts.
8.3.73
MCP Maximum Gain
Function
Command String
Camera Response
Set MCP Max Gain
:MXG=[DDD]<cr> :o<cr>
Set the MCP maximum gain. [DDD] is the gain code value with
a range of 0-255. This is equivalent to a gain voltage of 2.5-5.0
volts.
Get MCP Max Gain
:MXG?<cr> :oMXG[DDD]<cr>
Enquire current MCP maximum gain. [DDD] is the current max
code value with a range of 0-255. This is equivalent to a gain
voltage of 2.5-5.0 volts.
8.3.74
Color Balance – Red
Function
Command String
Camera Response
Set Red Balance
:RBL=[DDD]<cr> :o<cr>
Set the red color balance in the AFE. [DDD] is the color
balance value with a range of 0-511.
Get Red Balance
:RBL?<cr> :oRBL[DDD]<cr>
Enquire current red color balance. [DDD] is the current
balance value with a range of 0-511.