Appendix 69
RMC-675/RMC-673
8.3.67
MCP Manual Gate
Function
Command String
Camera Response
Set MCP Manual Gate
:MGA=[DDD]<cr> :o<cr>
Set the MCP manual gate value. [DDD] is the gate code value
with a range of 1-255. This is equivalent to a gate range of
0.065-17 msec.
Therefore there are 14.99 count/msec.
Get MCP Manual Gate
:MGA?<cr> :oMGA[DDD]<cr>
Enquire current MCP manual gate. [DDD] is the current gate
code value with a range of 1-255. This is equivalent to a gate
range of 0.065-17 msec.
Therefore there are 14.99
count/msec.
8.3.68
MCP Manual Gain
Function
Command String
Camera Response
Set MCP Manual Gain
:MGN=[DDD]<cr> :o<cr>
Set the MCP manual gain value. [DDD] is the gain code value
with a range of 0-255. This is equivalent to a gain voltage of
2.5-5.0 volts.
Get MCP Manual Gain
:MGN?<cr> :oMGN[DDD]<cr>
Enquire current MCP manual gain. [DDD] is the current gain
value with a range of 0-255. This is equivalent to a gain
voltage of 2.5-5.0 V.
8.3.69
Mirror Image Mode
Function
Command String
Camera Response
Turn Mirror Image On/Off
:MIR=[D]<cr> :o<cr>
Turn the mirror image feature on and off. [D] is the feature
state.
0 = Off (Normal Image).
1 = On. (Image Reversed Horizontally)
Get Mirror Image State
:MIR?<cr> :oMIR[D]<cr>
Enquire current mirror image feature state. [D] is the current
mode value.
0 = Off (Normal Image).
1 = On. (Image Reversed Horizontally)
8.3.70
MCP Level
Function
Command String
Camera Response
Set MCP Level
:MLV=[DDD]<cr> :o<cr>
Set the MCP level. [DDD] is the level value with a range of
200-800.
Get MCP Level
:MLV?<cr> :oMLV[DDD]<cr>
Enquire current MCP level. [DDD] is the current bias value with
a range of 200-800.