8.3.12
Binning for ALC
Function
Command String
Camera Response
Set Binning
:BIN=[D]<cr> :o<cr>
Turn binning for automatic level control on/off. [D] is the
state value.
0 = Binning off.
1 = Binning on
Get Binning
:BIN?<cr> :oBIN[D]<cr>
Enquire current binning state for automatic level control. [D]
is the current state value.
0 = Binning off.
1 = Binning on.
8.3.13
Current Image Brightness
Function
Command String
Camera Response
Get Current Brightness
:BRT?<cr> :oBRT[DDD]<cr>
Enquire current image brightness. [DDD] is the current image
brightness value with a range of 0-4095.
8.3.14
Blemish Count
Function
Command String
Camera Response
Get Blemish Count
:BCT?<cr> :oBCT[DDD]<cr>
Enquire current blemish count. The camera keeps a list of
blemish pixels that are bright regardless of the input signal.
This function returns the number of blemishes that have been
identified for this camera. [DDD] is the returned count value.
8.3.15
Blemish Threshold
Function
Command String
Camera Response
Set Blemish Threshold
:BTH=[DDD]<cr> :o<cr>
Set the threshold value that the camera will use as a
comparison value to identify blemish pixels that are bright
regardless of the input signal. Any pixel with a count value
higher than the blemish threshold will be marked as a blemish
pixel. [DDD] is the threshold value and has a range of 0-1023.
Get Blemish Threshold
:BTH?<cr> :oBTH[DDD]<cr>
Enquire current blemish threshold value. The camera uses this
threshold as a comparison value to identify blemish pixels that
are bright regardless of the input signal. Any pixel with a
count value higher than the blemish threshold will be marked
as a blemish pixel. [DDD] is the threshold value and has a
range of 0-1023.