RMC-675/RMC-673
74
Appendix
8.3.84
SMX – Max ALC Shutter Speed
Function
Command String
Camera Response
Set ALC Max Shutter Speed
:SMX=[DDD]<cr> :o<cr>
Set the max shutter speed value the ALC mode can use. [DDD]
is the shutter speed value with a range of 1-260 (NTSC models)
or 1-310 (PAL models). This controls the maximum shutter
speed that the ALC algorithm will use.
Get ALC Max Shutter Speed
:SMX?<cr> :oSMX[DDD]<cr>
Enquire current SMX max value. [DDD] is the shutter speed
value with a range of 1-260.
8.3.85
SNO Factory Unit ID String
Function
Command String
Camera Response
Get Factory Unit ID String
:SNO?<cr> :o
[XXX….]<cr>
Enquire the camera’s factory assigned ID string value in the
camera’s EEPROM memory. [XXX…]
The returned string is up to 16 ASCII characters made up of a 6
digit ID no, followed by an 8-digit date code, and a 2-digit
revision code.
Note: This feature applies to the TM-770, TM-
773, and TM-775.
8.3.86
SSX – Max Shutter Speed
Function
Command String
Camera Response
Get Max Shutter Speed
:SSX?<cr> :oSXX[DDD]<cr>
Enquire maximum allowable value for shutter speed. Different
camera models may have a different shutter speed range.
[DDD] is the shutter speed value with a range of 1-260 (NTSC
models) or 1-310 (PAL models).
8.3.87
Trigger Mode
Function
Command String
Camera Response
Set Trigger Mode
:TMD=[D]<cr> :o<cr>
Set the Trigger mode. [D] is the mode parameter.
0 = Off.
1 = Async Reset.
2 = Edge Pre-select.
3 = Pulse Width Mode.
Get Trigger Mode
:TMD?<cr> :oTMD[D]<cr>
Enquire current Trigger mode. [D] is the current mode value.
0 = Off.
1 = Async Reset.
2 = Edge Pre-select.
3 = Pulse Width Mode.