GUI Features
TM/
TMC/RM/RMC-2030GE
- 38 -
Figure 43. Table drop down menu:
The Table drop down menu offers three options.
The Linear option gathers light in a proportional manner. In this particular selection the LUT is config-
ured to speed the light gathering capability at the beginning of the exposure.
The Gamma.45 option is designed to cause the camera to gather light for a result very similar to
what the human eye sees. The heavier curved blue line represents the Gamma.45 LUT adjustment.
Figure 44. Gamma.45 imitates human eye sensitivity when creating an image.
The knee setting allows two adjustments in the light gathering configuration of the LUT to permit the
camera to correct images as they are captured. It is possible to set knees on any of the drop down
settings by clicking on the existing curve and moving it to the desired configuration. If a drop-down
menu setting is selected without adjusting the knees, the camera sets the default.
Summary of Contents for RM-2030GE