Configuring the TM-2030GE Camera
TM/
TMC/RM/RMC-2030GE
- 16 -
3.4.5 Look-Up Table
The look-up table (LUT) control, shown in Figure 21, allows you to change two knee point values.
Figure 21. Look-Up Table
Enter X
1
, Y
1
, X
2
, Y
2
values directly to adjust the knee curve. In the integrated camera software, the
look-up table can also be controlled interactively. The Table Selection pull-down menu allows you to
select the Linear or Gamma 45 option. This control also allows you to check the positive or negative
box to choose an image option. There is no LUT for 12-bit output.
3.4.6 Memory Pages
All the camera parameters such as shutter mode, shutter speed, gain, offset level, scan mode, and
LUT can be saved into seven available memory pages on the EEPROM in the camera. The pages are
numbered 0-6. The Load Page button loads the corresponding camera settings from the EEPROM while
the write page button writes the current camera settings to the corresponding memory page in the
EEPROM.
Page 1, shown in Figure 22, is the power-up default page. Page 0 is the factory default. To save your
current camera settings for power up default, write the settings to memory page 1.
Summary of Contents for RM-2030GE
Page 1: ...User s Manual Document Version C Document P N 10446 TM TMC 2030GE Progressive Scan Cameras ...
Page 2: ...TM TMC RM RMC 2030GE ii ...
Page 5: ...TM TMC RM RMC 2030GE v ...
Page 6: ...TM TMC RM RMC 2030GE vi ...
Page 10: ...Table of Contents TM TMC RM RMC 2030GE x ...
Page 14: ...List of Tables TM TMC RM RMC 2030GE xiv ...
Page 77: ...Operation TM TMC RM RMC 2030GE 63 Figure 63 Field Video Timing Continuous Mode ...
Page 83: ......