Signal Handling
TM/
TMC/RM/RMC-2030GE
- 24 -
4.5 Pulse Generators
The TM-2030GE camera has four independently programmable pulse generators. These generators
can run as either periodic or triggered. To run the pulse generators as triggered, they can be trig-
gered on either levels or signal edges. These generators can be tied to the camera inputs (camera-
control lines). For example, you can set pulse generator 0 in the Device Features tabbed dialog box to
the following values:
Delay = 600
Width = 14,000
Granularity = 1
Now check the Periodic option and change the camera settings to Async 9. This triggers the camera,
based on the pulse width set in the Pulse Generator page.
Be careful with the pulse generator’s GPIO input and output polarity. If the delay and pulse-width
duration are switched around, the output polarity must be negated in the GPIO lookup table.
The pulse generators are configured in the
Pulse Generator
section of the
Device Features
tab of the
Advanced Configuration window as shown in Figure 27.
Figure 27. Pulse Generator Page