GigE Series Camera Serial Commands
TM/
TMC/RM/RMC-2030GE
- 25 -
5 GigE Series Camera Serial Commands
You can control the GigE series cameras by serial command either using RS-232 or Camera Link. The
Start character is always “:” and the End character is always <CR> (return). For example, to set Asyn-
chronous Pulse Width Mode, send the command :ASH=9<CR> to the camera. Table 4 lists serial com-
mands that can be used to control the camera.
Table 4. TM/TMC-2030GE Command List
Command
Parameter
End of Cmd
Ack. Response
Description
Scan Mode
Shutter Mode and Shutter Speed
:MSH=
X
<cr>
:o<cr>
Set Continuous Mode Preset Shut-
ter ( X= 0)
:DSH=
XXX
<cr>
:o<cr>
Set Continuous Mode Programmable
Shutter ( XXX=000 - total lines)
:ASH=
X
<cr>
:o<cr>
Set Async Mode Preset Shutter (X=0,
9, A, B) ( X=0 async no shutter)
( X=9 PWC, X=A Fixed exposure PIV,
X=B PWC PIV)
:ADS=
XXX
<cr>
:o<cr>
Set Async Mode Programmable Shut-
ter (XXX=000 - 81F)
:SHR?
<cr>
:o[shtr]<cr>
Inquire current shutter mode
Gain and Offset
:MGA=
XXX
<cr>
:o<cr>
Set Master Gain
(XXX = 000 - FFF)
:MGB=
XXX
<cr>
:o<cr>
Set R channel Fine Gain
(XXX = 000 - FFF)
:VRA=
XXX
<cr>
:o<cr>
Set Master Offset
(XXX = 000 - FFF)
:VRB=
XXX
<cr>
:o<cr>
Set R channel Fine Offset
(XXX = 000 - FFF)
:MGA?
<cr>
:oMG[XXX]<cr>
Inquire Master Gain
(XXX = 000 - FFF)
:MGB?
<cr>
:oSG[XXX]<cr>
Inquire R channel Fine Gain (XXX =
000 - FFF)
:VRA?
<cr>
:oMF[XXX]<cr>
Inquire Master Offset
(XXX = 000 - FFF)
:VRB?
<cr>
:oSF[XXX]<cr>
Inquire R channel Fine Offset
(XXX = 000 - FFF)
Lookup Table
:LINR
<cr>
:o<cr>
Set linear table
:GM45
<cr>
:o<cr>
Set gamma .45 table
:KNEE=
X1Y1X2Y2
<cr>
:o<cr>
Set knees
(X1, Y1, X2, Y2 = 00 - FF)
Summary of Contents for RM-2030GE
Page 1: ...User s Manual Document Version C Document P N 10446 TM TMC 2030GE Progressive Scan Cameras ...
Page 2: ...TM TMC RM RMC 2030GE ii ...
Page 5: ...TM TMC RM RMC 2030GE v ...
Page 6: ...TM TMC RM RMC 2030GE vi ...
Page 10: ...Table of Contents TM TMC RM RMC 2030GE x ...
Page 14: ...List of Tables TM TMC RM RMC 2030GE xiv ...
Page 77: ...Operation TM TMC RM RMC 2030GE 63 Figure 63 Field Video Timing Continuous Mode ...
Page 83: ......