Configuring the TM-2030GE Camera
TM/
TMC/RM/RMC-2030GE
- 18 -
The XML file will not, however, save camera parameters such as shutter mode, shutter speed, gain
settings, offset level, scan mode, and LUT. For more information about saving these camera parame-
ters, please refer to Section 3.4.6, “Memory Pages,” on page 16.
3.4.11 White Balance Control (Color Versions Only)
To determine white balance, use the following steps:
1. Select scan mode A and no binning in the GigE Camera Software tabbed dialog. shown in
2. Start the live video by clicking
Start
in the Acquisition tab of the Camera Interface Application
dialog box.
3. Select
Color Adjustment
under tools in the main menu. Show the camera a piece of white paper
to make sure that the image is not saturated.
4. Click
Analyze
to automatically calculate the white balance.
5. Once white balance has been calculated, click
Apply Results
to apply the white balance. You can
also assign custom gain and offset values to the R, G, and B channels. If you choose to assign cus-
tom values, click
Apply Results
.
Figure 23.
White Balance Control Settings.
3.4.12 Main Menu: “Option”
3.4.12 (a) Test Pattern
The Grabber Settings tabbed dialog box has a check box to enable the test pattern that is internally
generated by the integrated camera software.
Custom white
balance.
Gain/Offset
Automatic white
balance control.
Summary of Contents for RM-2030GE
Page 1: ...User s Manual Document Version C Document P N 10446 TM TMC 2030GE Progressive Scan Cameras ...
Page 2: ...TM TMC RM RMC 2030GE ii ...
Page 5: ...TM TMC RM RMC 2030GE v ...
Page 6: ...TM TMC RM RMC 2030GE vi ...
Page 10: ...Table of Contents TM TMC RM RMC 2030GE x ...
Page 14: ...List of Tables TM TMC RM RMC 2030GE xiv ...
Page 77: ...Operation TM TMC RM RMC 2030GE 63 Figure 63 Field Video Timing Continuous Mode ...
Page 83: ......