6.3.4 Shutter-Select mode with internal trigger
In this mode, the exposure and readout is activated by the trigger pulse generated internally.
As the accumulation control is done by the internal counter, the accumulation is not affected by
the trigger jitter.
In this mode, the exposure time of R, G, B and NIR channel can be adjusted independently.
To use this mode:
Set function
Trigger mode, Shutter-Select
TR=1
Line rate
LR=4602 to 1201920
(54.79 μs to 14.30 ms in 11.9 ns increments)
Trigger origin, internal
TG=0
Individual R, G, B and NIR exposure EI=0(individual)
EI=1(tracking with G)
Programmable exposure
PER/PEG/PEB/PEIR=840 to 1194752
(9.52 µs to 14.2 ms in 11.9 ns increments)
Important note:
If using individual exposure, the EEN signal represents the channel with the longest exposure
time
For one-push white balance, both shutter gain (AH) and gain( AW) are effective.
Note: EEN uses channel with the largest exposure value
Fig.38 Shutter-Select mode / Internal
EEN
* Note
Exposure R
Exposure G
Exposure B
Exposure NIR
610clk
LVAL
16clk
4096clk
16clk
DVAL
Data
AP0
AP4095