LQ-401CL
46
Individual
Settings:
G ch: 0 to 64
Associated functions:
Commands BLR, BLB, BLIR
7.10 Commands BLR, BLB and BLIR – Black Level Red, Blue and NIR
In conjunction with Command BL, these commands allow individual setting of the black level in all
channels.
Master Tracking
Settings:
-64 to 63
This parameter is adjusted to Master setting value
Individual
Settings
0 to 64
Associated functions:
Command BL
7.11 Command BLM - Black Level Mode
Select the black level adjustment method
Settings
0=Master tracking
(
Factory default
)
1=Individual
7.12 Command CABR, CABB and CABIR Chromatic aberration Red, Blue NIR
These commands compensate the size of image on sensor. The size of image on the sensor may be
different on R,G,B and NIR channels due to the prism optics which is called lateral chromatic
aberration.
There are 112 data elements. In order to write all data, this command must be written 112 times.
Please refer to the chapter 6.2.11 for the details of this function
Associated commands: MAV, MAVCG,CABN1, CABN2, CABN3, CABLR, CABLB, CABLIR
CABAR, CABAB, CABAIR, CABSR, VABSB, CABSIR, CABTR, VABTB
CABTIR
7.13 Command EI – Interlocked R, G, B & NIR Exposure
When this function is enabled (interlocked), exposure time for all four channels is selected by
setting the green channel and the red, blue and NIR channels will track.
To obtain white balance, adjust red and blue channels using PER and PEB. Thereafter, it is
possible to adjust overall exposure time by using the command PEG. The red and blue channels
will track the green channel proportionally, thus maintaining white balance settings.
Settings:
0= OFF(independent R, G,B and NIR settings)
1= R, B and NIR channel tracking with G
Associated functions:
Commands PER, PEG, PEB and PEIR – Programmable Exposure
Applicable modes:
Shutter-Select mode only