LQ-401CL
38
Note: EEN uses channel with the largest exposure value
Fig.43 Shutter-Select /Sub-sampling and Window/ External
6.3.6 Pulse Width Control (PWC) mode
In this mode, the exposure time and readout are activated by the external trigger pulse. The
exposure time depends on the pulse width provided.
To use this mode:
Set function
Trigger mode, PWC
TR=2
Important Note:
The minimum trigger interval
Scan mode
Trigger input via
Minimum interval (
µ
s)
Full/Binning
Camera link
Exposure time + 52.6
12-pin
Exposure time + 57.1
Sub-sampling/windowing
Camera link
Exposure time + 30.4
12-pin
Exposure time + 34.9
The minimum trigger pulse width
Trigger input via
Minimum trigger pulse width
Camera link
52.6 µs
12-pin
57.1 µs
One-push white balance by gain setting only.
When the one-push white balance has been initiated and the rear panel LED shows orange, the
camera must receive continuous external trigger pulses corresponding to the frequency and
duty cycle used in the application.
TG
156clk
EEN
* Note
Exposure R
Exposure G
Exposure B
Exposure NIR
610clk
LVAL
16clk
2048clk
16clk
DVAL
Data
AP0
AP2047