LQ-401CL
28
White
Fig.31 White test pattern
6.3.
Operation modes
The LQ-400CL has the following operation modes.
Trigger Mode
Trigger origin
Command
Description
Command
Description
1
TR=0
No-Shutter
TG=0
Internal
2
TG=1
External
3
TR=1
Shutter select
TG=0
Internal
4
TG=1
External
5
TR=2
Pulse width control
TG=1
-
6.3.1 Camera Default Settings
The following table shows the default settings of LQ-401CL
Item
Default setting
Value
Gain
Master mode B/G/R/NIR
0dB
Black
Master mode B/G/R/NIR
8LSB
Trigger Mode
No-shutter
Trigger Origin
Internal
Auto Reset Mode
ON
Input
Camera Link
Polarity
Active Low
Line Rate
24000
Bit Allocation
8-bit
Binning
OFF
Test Pattern
OFF
Noise Reduction
OFF
0
32( 8)
0
890( 222)
DVAL
Si gnal
(
RGB
)
4095