66
̶
GO-2400M-PMCL / GO-2400C-PMCL
Function name
Access
type
Setting range
Min. value
Max. value
Default value
Description
Sequence Roi
Offset X
R/W
0 to 1840
0
1840
0
Set the Offset X of the
selected Sequence
Roi Index.
Sequence Roi
Offset Y
R/W
0 to 1214
0
1214
0
Set the Offset Y of the
selected Sequence
Roi Index.
Sequence Roi V
Binning
R/W
1 to 2
1
2
1
Set the Horizontal
Binning of the
selected Sequence
Roi Index.
(Mono only)
Sequence Roi
Black Level
R/W
1 to 2
1
2
1
Set the Vertical
Binning of the
selected Sequence
Roi Index.
(Mono only)
Sequence Roi
Exposure Time
R/W
15 to 8000000*
15 *
8000000 *
8000
Set the exposure time
of the selected
Sequence Roi Index.
Sequence Roi
Gain
R/W
100 to 1600
100
1600
100
Set the gain of the
selected Sequence
Roi Index.
Sequence Roi
Gain Red
R/W
–4533 to +37876
–4533
37876
0
Set the red gain of
the selected
Sequence Roi Index.
Sequence Roi
Gain Blue
R/W
–4533 to +37876
–4533
37876
0
Set the blue gain of
the selected
Sequence Roi Index.
Sequence Roi H
Binning
R/W
–133 to +255
–133
255
0
Set the black level of
the selected
Sequence Roi Index.
Sequence Lut
enable
R/W
True, False
—
—
FALSE
Enable/disable the
LUT setting for the
selected Sequence
Roi Index.
Sequence LUT
Mode
R/W
Gamma
LUT
—
—
Gamma
Select the LUT mode
to use during Trigger
Sequence Mode and
Command Sequence
Mode. (This setting is
applied when
Sequence Roi Lut
Enable is set to
"True.")
Command
Sequence Index
R/O
—
1
128
0
Set the index
displayed during
Command Sequence
Mode.
Current
Sequence Index
R/W
—
—
Display the index
number of the
currently displayed
image.
Reset Sequence
Index
W/O
—
—
—
—
Reset the current
index number for
Trigger Sequence
Mode and Command
Sequence Mode to
"Index 1."
Sensor Multi Roi
Index
R/W
Index1 [Index 1]
Index2 [Index 2]
Index3 [Index 3]
Index4 [Index 4]
—
—
Index1
Select the index for
Sensor Multi Roi
Mode.
Sensor Multi Roi
Width
R/W
96 to 1936
96
1936
1936
Set the width of the
selected Sensor Multi
Roi Index.
Sensor Multi Roi
Height
R/W
2 to 1216
2
1216
1216
Set the height of the
selected Sensor Multi
Roi Index.