58
̶
GO-2400M-PMCL / GO-2400C-PMCL
Function name
Access
type
Setting range
Min. value
Max. value
Default value
Description
Offset X
R/W
Min to Max
0
1840
0
Set the horizontal
offset.
Offset Y
R/W
Min to Max
0
1214
0
Set the vertical offset.
Binning
Horizontal
R/W
1: Off
2: x2
1
2
1: Off
Set the number of
pixels in the
horizontal direction
for which to perform
binning.
(Mono only)
Binning Vertical
R/W
1: Off
2: x2
1
2
1: Off
Set the number of
pixels in the vertical
direction for which to
perform binning.
GO-400M-PMCL only
Pixel Format
R/W
GO-2400M-PMCL:
Mono8
Mono10
Mono12
GO-2400C-PMCL:
BayerRG8
BayerRG10
BayerRG12
—
—
GO-2400M-PMCL:
Mono8
GO-2400C-PMCL:
BayerRG8
Set the pixel format.
Mono12 and
BayerRG12 are
available when Video
Process Bypass
Mode is set to On.
PixelColorFilter
R/O
GO-2400M-PMCL:
None
GO-2400C-PMCL:
BayerRG
—
—
GO-2400M-PMCL:
None
GO-2400C-PMCL:
BayerRG
Display the color filter
type that will be
applied to the image.
Test Pattern
R/W
Off [Off]
GreyHorizontalRamp [Grey
Horizontal Ramp]
GreyVerticalRamp [Grey Vertical
Ramp]
GreyHorizontalRampMoving
[Grey Horizontal Ramp Moving]
HorizontalColorBar [Horizontal
Color Bar]
VerticalColorBar [Vertical Color
Bar]
MovingColorBar [Moving Color
Bar]
—
—
0: Off
Select the test image.
ColorBar is only
available on the
GO-2400C-PMCL.
c) Acquisition
Control
Configure image
capture settings.
Acquisition
Frame Rate Raw
R/W
0.125 to 127.975
0.125
127.975
120.163
Set the frame rate as
a frequency. (unit: Hz)
The maximum value
varies depending on
the TapGeometory
and ROI settings.
Trigger Selector
R/O
FrameStart
[Frame Start]*
—
—
FrameStart
Select the trigger
operation.
Trigger Mode
R/W
Off
On
—
—
Off
Display the Trigger
mode.
Trigger Software
W/O
—
—
—
—
Execute a software
trigger.
Trigger Source
R/W
Low [Low]
High [High]
Software [Software]
PulseGenerator0 [Pulse
Generator 0]
UserOutput0 [User Output 0]
UserOutput1 [User Output 1]
Line4 [Line4 - TTL In]
Line 7[Line7 - CC1]
Nand0 [Nand0 Out]
Nand1 [Nand1 Out]
—
—
Line 7 [Line7- CC1]
Select the trigger
signal source.
Line4 TTL In is
available on Standard
Model.
Trigger Activation R/W
RisingEdge [Rising Edge]
FallingEdge [Falling Edge]
LevelHigh [Level High]
LevelLow [Level Low]
—
—
Rising Edge
Select the polarity of
the trigger signal (i.e.,
location of signal at
which trigger is
applied).